## [I/O signals not showing in OPC UA client](https://tech-community.robotics.abb.com/t/i-o-signals-not-showing-in-opc-ua-client/11872)

<div class="topic-metadata">

**Author:** [@poiuyt](https://tech-community.robotics.abb.com/u/poiuyt)\
**Replies:** 3\
**Last updated:** [November 5, 2025, 10:59am UTC](https://tech-community.robotics.abb.com/t/i-o-signals-not-showing-in-opc-ua-client/11872 "2025-11-05T10:59:22Z")

</div>

I managed to establish connection between Robotstudio and UAexpert the OPC UA client I am currently using. The problem is that whenever I go in to the I/O signals folder in the OPC UA client, there are no signals or tags…

---

## [IoT Gateway and OPC UA Limitations](https://tech-community.robotics.abb.com/t/iot-gateway-and-opc-ua-limitations/11560)

<div class="topic-metadata">

**Author:** [@jjwempe2](https://tech-community.robotics.abb.com/u/jjwempe2)\
**Replies:** 0\
**Last updated:** [August 21, 2024, 7:38pm UTC](https://tech-community.robotics.abb.com/t/iot-gateway-and-opc-ua-limitations/11560 "2024-08-21T19:38:11Z")

</div>

Two questions with details written below: Is an OPC UA client able to write to PERS arrays? Is an OPC UA client able to write negative values to an analog input/output? I can successfully communicate with an IRC…

---

## [Writing from virtual controller Profinet signals to PLC through OpcUa](https://tech-community.robotics.abb.com/t/writing-from-virtual-controller-profinet-signals-to-plc-through-opcua/10965)

<div class="topic-metadata">

**Author:** [@dragolollo](https://tech-community.robotics.abb.com/u/dragolollo)\
**Replies:** 2\
**Last updated:** [February 13, 2023, 3:07pm UTC](https://tech-community.robotics.abb.com/t/writing-from-virtual-controller-profinet-signals-to-plc-through-opcua/10965 "2023-02-13T15:07:33Z")

</div>

Hello all, I would like to simulate ProfiNet communication between the virtual controller and Siemens PLC using OpcUa. I have configured the OpcUa client in RobotStudio assigning the ProfiNet device to an array of Usint…

---

## [Robotstudio manual, chapter: Virtual commissioning using the OPC UA Client Smart Component](https://tech-community.robotics.abb.com/t/robotstudio-manual-chapter-virtual-commissioning-using-the-opc-ua-client-smart-component/10496)

<div class="topic-metadata">

**Author:** [@czagawara](https://tech-community.robotics.abb.com/u/czagawara)\
**Replies:** 3\
**Last updated:** [December 21, 2021, 11:08am UTC](https://tech-community.robotics.abb.com/t/robotstudio-manual-chapter-virtual-commissioning-using-the-opc-ua-client-smart-component/10496 "2021-12-21T11:08:46Z")

</div>

Hi all, First, why is so hard to find manulas ???!!! Where I can find this manual of Robotstudio with “Virtual commissioning using the OPC UA Client Smart Component” chapter ?? TIA Bart